Arq. bras. oftalmol ; 82(3): 207-213, May-June 2019. tab, graf
Article in English | LILACS | ID: biblio-1001311

ABSTRACT

ABSTRACT Purpose: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes. Methods: Twenty-four subjects with healthy, phakic eyes, whose mean age was 27.1 ± 8.9 years, underwent measurement with an anterior chamber optical coherence tomographer. The anterior ciliary muscle was measured at the nasal, temporal, superior, and inferior sectors for 0, -1, -2, and -3 D of vergence. A linear model was used to assess the correlation of each eye parameter with the accommodative demand. Results: The anterior ciliary muscle area significantly increased with accommodation for each sector, with a maximum increase of about 30% for the nasal-temporal sectors and about 25% for the inferior-temporal sectors. The linear model showed a tendency toward a positive relationship between change in the ciliary muscle area of each sector and vergence. Conclusion: The anterior ciliary muscle area tends to increase with accommodation, although the increase has been shown to be symmetric between the pair sectors superior-nasal and inferior-temporal. These results may help to increase understanding of accommodation biometry and biomechanics.


RESUMO Objetivo: Medir as alterações do músculo ciliar anterior durante a acomodação nos setores nasal, superior, temporal e inferior, através de um tomógrafo de coerência óptica de câmara anterior, e correlacioná-las com alterações de vergência. Métodos: Vinte e quatro indivíduos com olhos saudáveis e fácicos, com idade média de 27,1 ± 8,9 anos, foram submetidos à medida com um tomógrafo de coerência óptica de câmara anterior. O músculo ciliar anterior foi medido nos setores nasal, temporal, superior e inferior para 0, -1, -2 e -3D de vergência. Um modelo linear foi utilizado para avaliar a correlação de cada parâmetro do olho com a demanda acomodativa. Resultados: A área do músculo ciliar anterior aumentou significativamente com a acomodação em cada setor, com um aumento máximo foi de cerca de 30% para os setores naso-temporais, e cerca de 25% para os inferiores-temporais. O modelo linear mostrou uma tendência para uma relação positiva entre a alteração da área do músculo ciliar de cada setor e a vergência. Conclusão: A área do músculo ciliar anterior tende a aumentar com a acomodação, embora o aumento tenha se mostrado simétrico entre os setores superior-nasal e inferior-temporal. Estes resultados podem ajudar a aumentar a compreensão da biometria e biomecânica da acomodação.


Subject(s)
Humans , Male , Female , Adult , Young Adult , Ciliary Body/physiology , Ciliary Body/diagnostic imaging , Tomography, Optical Coherence/methods , Accommodation, Ocular/physiology , Reference Values , Biomechanical Phenomena , Linear Models , Analysis of Variance , Biometry/methods , Statistics, Nonparametric
2.
Arq. bras. oftalmol ; 82(2): 129-135, Mar.-Apr. 2019. graf
Article in English | LILACS | ID: biblio-989398

ABSTRACT

ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significant changes in axial length, central corneal thickness, anterior chamber depth, and keratometric measurements with soft contact lenses as compared to the naked eye (p<0.001). However, there were no significant differences in lens thickness outcomes between the naked eye and while wearing the three soft contact lenses (p>0.5). The changes in axial length, central corneal thickness, and anterior chamber depth were lens-specific and dependent on the thickness of the lens used. Conclusions: Sept-source optical coherence tomography based lens thickness measurements while wearing soft contact lenses are comparable to those of the naked eye. However, the thickness and the optical design of the soft contact lens may lead to significant differences in the axial lengh, central corneal thickness, anterior chamber deph, and keratometric measurements.


RESUMO Objetivo: Determinar a confiabilidade da tomografia de coerência óptica de varredura em casos especiais em que lentes de contato gelatinosas não podem ser removidas ao realizar medições biométricas. Métodos: Oito indivíduos foram incluídos e apenas um olho por participante foi analisado. Cada olho foi medido seis vezes por tomografia de coerência óptica de varredura com o instrumento IOLMaster 700 (Carl Zeiss Meditec, Jena, Alemanha). O comprimento axial, a espessura central da córnea, a profundidade da câmara anterior, a espessura da lente e as medidas ceratométricas foram avaliados a olho nu e enquanto usavam lentes de contato gelatinosas de três diferentes potências (-1,5, -3,0 e +2,0 D). Resultados: Houve alterações significativas no comprimento axial, espessura central da córnea, profundidade da câmara anterior e medidas ceratométricas com as lentes de contato gelatinosas em comparação com as a olho nu (p<0,001). No entanto, não houve diferenças significativas nos resultados de espessura do cristalino entre o olho nu e enquanto usava as três lentes de contato gelatinosas (p>0,5). As alterações de comprimento axial, espessura central da córnea e profundidade da câmara anterior foram específicas da lente e dependentes da espessura da lente usada. Conclusões: As medições da espessura da lente baseadas na tomografia de coerência óptica da Sept-source, enquanto usam lentes de lentes de contato gelatinosas, são comparáveis às do olho nu. Entretanto, a es pessura e o desenho óptico da lente de contato gelatinosa podem levar a diferenças significativas no comprimento axial, na espessura central da córnea, na profundidade da câmara anterior e nas medidas ceratométricas.


Subject(s)
Humans , Adult , Biometry/methods , Contact Lenses , Tomography, Optical Coherence/methods , Axial Length, Eye/anatomy & histology , Axial Length, Eye/diagnostic imaging , Anterior Eye Segment/anatomy & histology , Anterior Eye Segment/diagnostic imaging , Reference Values , Reproducibility of Results , Analysis of Variance , Statistics, Nonparametric , Cross-Over Studies
3.
Arq. bras. oftalmol ; 77(4): 243-249, Jul-Aug/2014. tab, graf
Article in English | LILACS | ID: lil-728661

ABSTRACT

Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained for various accommodation stimuli, ranging from +1 D to -4 D in 1-D steps. Results: For a given position, the ACD did not vary significantly with accommodation. For the central ACD, the percentage of relative change between far and near vision was -4.11%. The ACA was significantly lower at the inferior, temporal, and superior positions. There was no change in the ACA of the whole eye and that of the nasal orientation. These two eye metrics were significantly lower in the superior-nasal than in the inferior-temporal region. At each vergence studied, the PD decreased significantly with accommodation. The relative change after the -4 D stimulus was -8.13%. Conclusion: ACA and PD varied significantly with accommodation, whereas no such variation of ACD was observed. Further, the anterior chamber was found to be asymmetrical, with the nasal-superior area becoming significantly shallower than the inferior temporal region. .


Objetivo: Estudar as mudanças na profundidade da câmara anterior (ACD), ângulo da câmara anterior (ACA) e diâmetro da pupila (PD) durante a acomodação. Métodos: Foram incluídos 80 olhos de 80 indivíduos com idades entre 22 e 40 anos. Um sistema rotacional de Scheimpflug duplo acoplado a um sistema de disco de Placido (Galilei G4, Ziemer Ophthalmic Systems AG, Suíça) foi usado para medir as mudanças na ACD, ACA e PD, durante a acomodação. As medidas da ACD foram consideradas na zona central e em mais 4 posições, cada uma em orientação diferente (nasal, superior, temporal e inferior), a 4 milímetros de distância do centro. O ACA do olho inteiro, assim como nos quadrantes nasal, superior, temporal e inferior foram medidos. Todos estes indicadores foram obtidos por vários estímulos acomodativos, que variaram de +1 D a -4 D em intervalos de 1 D. Resultados: A ACD não variou significativamente com acomodação para qualquer determinada orientação, sendo a percentagem de variação relativa entre longe e visão de perto -4,11% para a ACD central (onde sinal negativo representa uma diminuição na ACD). Em relação ao ACA, este diminuiu significativamente em posições inferiores, temporais e superiores. O ACA total de olho e o ACA nasal não se alterou. Estas duas métricas oculares foram significativamente menores no par nasal-superior do que no temporal-inferior. Finalmente, PD diminuiu significativamente com a acomodação em cada vergência estudada, a mudança relativa após o estímulo de -4 D foi -8,13%. Conclusão: ACA e PD variaram significativamente com a acomodação, enquanto ACD não. Além disso, a câmara anterior se mostrou alterar assimetricamente, com a área nasal-superior se tornando ...


Subject(s)
Adult , Female , Humans , Male , Young Adult , Accommodation, Ocular/physiology , Anterior Chamber/anatomy & histology , Iris/anatomy & histology , Tomography, Optical Coherence/instrumentation , Diagnostic Techniques, Ophthalmological , Iris/physiology , Photography/instrumentation , Pupil/physiology
4.
Arq. bras. oftalmol ; 77(4): 233-237, Jul-Aug/2014. tab, graf
Article in English | LILACS | ID: lil-728664

ABSTRACT

Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured with the Galilei G4 and the Pentacam HR, respectively. The mean white-to-white distance measured was 11.84 ± 0.31 mm and 11.90 ± 0.43 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Mean pupil diameters were measured as 3.22 ± 0.58 mm and 3.22 ± 0.52 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Finally, the mean anterior chamber angle was 34.30 ± 2.86 degrees when it was measured with the Galilei G4, and 39.26 ± 2.85 degrees when measured with the Pentacam HR. A comparative analysis revealed that the Galilei G4 yielded a significantly lower (P<0.05) measurement for the anterior chamber depth, anterior chamber angle, and pupil diameter, than the Pentacam HR system. Comparable values (P>0.05) for both devices were obtained for the white-to-white distance measurements. Conclusion: The Galilei G4 and Pentacam HR Scheimpflug systems cannot be used interchangeably because they produce significant measurement differences. .


Objetivo: Avaliar a medida da profundidade da câmara anterior, distância branco a branco, ângulo da câmara anterior e diâmetro pupilar usando dois dispositivos de imagens de Scheimpflug diferentes. Métodos: Este estudo transversal incluiu 80 olhos direitos de 80 indivíduos com idades entre 20 e 40 anos. O equivalente esférico variou de -4,25 a +1,00 dioptrias (D). A profundidade da câmara anterior de cada olho, a distância branco a branco, o ângulo da câmara anterior e o diâmetro pupilar, foram medidos para visão de longe usando tanto o Galilei G4 (câmera de Scheimpflug dupla) e os sistemas Pentacam HR (câmera de Scheimpflug simples). Resultados: A profundidade média da câmara anterior foi 3,12 ± 0,23 mm e 3,19 ± 0,24 mm, usando o Galilei G4 e o Pentacam HR, respectivamente. A distância média da medida de branco a branco com o Galilei G4 foi 11,84 ± 0,31 mm e com o HR Pentacam foi 11,90 ± 0,43 mm. A média do diâmetro pupilar foi 3,22 ± 0,58 mm e 3,22 ± 0,52 mm, medidos com o Galilei G4 e o Pentacam HR, respectivamente. Finalmente, a média do ângulo da câmara anterior foi de 34,30 ± 2,86 graus quando foi medido com o G4 Galileu, e 39,26 ± 2,85 graus com o Pentacam HR. A comparação revelou que o dispositivo Galilei G4 mediu significativamente menor (P<0,05) profundidade da câmara anterior, ângulo da câmara anterior e diâmetro da pupila do que o sistema de Pentacam HR, enquanto valores comparáveis (P>0,05) entre os dois dispositivos Scheimpflug foram obtidos para as medidas da distância branco a branco. Conclusão: O Galileu G4 e o Pentacam HR não podem ser usados indiferentemente, devido ás diferenças entre os dois aparelhos terem sido significativas sob o ponto de vista clínico. .


Subject(s)
Adult , Humans , Young Adult , Anterior Chamber/anatomy & histology , Imaging, Three-Dimensional/instrumentation , Interferometry/instrumentation , Iris/anatomy & histology , Diagnostic Techniques, Ophthalmological , Pupil , Photography/instrumentation